Three-axis Fluxgate Sensor Error Correction

Authors

  • Shuting Xiao

DOI:

https://doi.org/10.54097/ajst.v1i1.243

Keywords:

Three-axis fluxgate sensor, Least Squares, Error correction

Abstract

When the ideal three-axis fluxgate sensor measures the magnetic field, its total magnetic field does not change with the attitude change of the sensor. However, due to the limitations of the existing sensor manufacturing and processing technology, the three-axis fluxgate sensor has errors, It may cause hundreds of thousands of nanometers of measurement error, so for high-precision magnetic detection, the analysis and correction of its errors are of great significance. Aiming at the above problems, this topic analyzes the error mechanism of the three-axis fluxgate sensor, establishes a mathematical model for error correction, and uses the ideal three-axis fluxgate sensor modulus value to be independent of the sensor attitude to correct the sensor to correct and compensate the sensor error. The correction algorithm proposed in this paper can complete the error correction of the sensor well, thereby obtaining high-quality magnetic field data, laying a good foundation for the subsequent magnetic target positioning, which has important practical significance.

Downloads

Download data is not yet available.

References

Guo Haipeng (2016). Reserch on target localization methods based on magnetic anomaly gradient signal detection[D]. University of Electronic Science and Technology of China,p.1-2.

Clem T R(1997).Progress in magnetic sensor technology for sea mine detection.Proc Spie,vol.3079,p.354-371.

D. Robbes(2006).Highly sensitive magnetometers—a review. Vol.129,no1-2, p.86–93.

G Vértesy;A Gasparics;J Szöllsy (2000). High sensitivity magnetic field sensor.Sensors and actuators , vol.85,no.1-3,p. 202-208.

Zhining Guan(2005). Geomagnetic Field and Magnetic Exploration [M]. Professor of Geophysics China University of Geosciences ( Beijing),p.54-66.

ZHANG Zhao-yang , XIAO Chang-han , YAN Hui(2009). Localization of a Magnetic Object Based on Magnetic Gradient Tensor at a Single Point. Journal of Detection &Control,vol.31,no.4,p.44-48.

Gao Quanming(2020). Research on system error calibration and interference compensation technology of aeromagnetic three-component survey based on fixed-wing UAV[D]. Jilin University,p. 6-9.

Primdahl, F; Jensen, P Anker (1982). Compact spherical coil for fluxgate magnetometer vector feedback. Journal of Physics E: Scientific Instruments, vol.15,no.2, p.221-226.

Bian Jiangwei(2016). Testing of UAV Aeromagnetic System and Calibration of Fluxgate sensor [D]. Chengdu University of Technology,p.26-27.

Gang, Yin; Yingtang, Zhang; Hongbo, Fan; GuoQuan, Ren; Zhining, Li (2015). Integrated calibration of magnetic gradient tensor system. Journal of Magnetism and Magnetic Materials, vol.374,p. 289–297.

I. Markovsky; A. Kukush; S. Van Huffel (2004). Consistent least squares fitting of ellipsoids.vol.98,no.1,p.177-194.

Qingde Li and J. G. Griffiths(2004), "Least squares ellipsoid specific fitting," Geometric Modeling and Processing.pp.335-340.

Downloads

Published

03-03-2022

Issue

Section

Articles

How to Cite

Xiao, S. (2022). Three-axis Fluxgate Sensor Error Correction. Academic Journal of Science and Technology, 1(1), 29-34. https://doi.org/10.54097/ajst.v1i1.243