Development and Implementation of Low Noise Acquisition and High Precision Time Synchronization Technology for Shallow Buried Microseismic Monitoring System
DOI:
https://doi.org/10.54097/n0te2817Keywords:
Microseismic acquisition system, optimal noise matching, GPS, high precision time synchronization.Abstract
Existing shallow-buried microseismic acquisition systems face significant challenges in deployment and maintenance, with noise performance often failing to meet the demands of modern microseismic detection techniques. Furthermore, these systems rely on internal clocks for timestamping, where frequency drift in crystal oscillators can result in substantial cumulative time errors. To address these limitations, this study develops a high-precision data acquisition channel by applying principles of minimum noise and impedance matching, alongside a comparative analysis of state-of-the-art ∆-Σ analog-to-digital converters (ADCs). The system achieves a short-circuit noise level below 1.5 μV @ 500 Hz, a dynamic range of 126.7 dB @ 500 Hz, and a signal-to-noise ratio (SNR) of 131.53 dB @ 500 Hz. Additionally, a high-precision time synchronization method is proposed, combining timestamp indexing and time interpolation to compensate for cumulative errors caused by ADC clock crystal drift. This method integrates a high-accuracy synchronization design based on GPS pulse-per-second (PPS) interrupts and GPS serial interrupts, achieving a synchronization accuracy of 0.688 μs between nodes.
Downloads
References
[1] Tian, R.Y. Lv, S.X. Lin, J. Zhang, L.H. Key techniques of single channel wireless storage seismograph. Chin. J. Geophys. 2017, 60, 4273–4281.
[2] Wang, S.J. Lu, C. You, Q.Y. Zhang, Y. Design of a low cost Non-Cable seismic acquisition station. Chin. J. Geophys. 2015, 58, 1425–1433.
[3] Jiang, X. Lin, J. Ye, F. Zheng, F. Separation of P–P and P–SV wavefields by high resolution parabolic Radon transform. J. Appl. Geophys. 2015, 119, 192–201.
[4] Karplus M S, Kaip G, Harder S H, et al. Shallow active-source imaging of an andesite dike in southern New Mexico: comparing Reftek Texan and Fairfield Z-Land recordings[C]//AGU Fall Meeting Abstracts. 2016, 2016: S41A-2722.
[5] Lu, C. Wang, S.J. Zhang, Y. Dai, K.S. Zhang, Y. A new Low-Cost No-Cable digital geophone for microtremor survey. Chin. J. Geophys. 2015, 58, 2148–2159.
[6] GUTENBERG, B., RICHTER, C. Magnitude and Energy of Earthquakes. Nature 176, 795 (1955).
[7] José M. de la Rosa, et al. Sigma-Delta Modulators: Tutorial Overview, Design Guide, and State-of-the-Art Survey, IEEE Transactions on Circuits and Systems I: Regular Papers, vol.58, no.1, pp.1-21, 2011.
[8] U. L. Rohde, A. K. Poddar and A. M. Apte, Getting Its Measure: Oscillator Phase Noise Measurement Techniques and Limitations, in IEEE Microwave Magazine, vol. 14, no. 6, pp. 73-86, Sept.-Oct. 2013.
[9] Jiang, J. Yang, R. Wang, B. Xiang, Y. Pang, W. Yang, J. Ye, B. Assessing Short-Term clock errors and drifts of temporary seismic networks using the active airgun source in Binchuan, Yunnan. Seismol. Res. Lett. 2019, 90, 2165–2174.
[10] Buono P L, In V, Longhini P, et al. Phase drift on networks of coupled crystal oscillators for precision timing[J]. Physical Review E, 2018, 98(1): 012203.
[11] Knappe, S. Gerginov, V. Schwindt, P.D.D. Shah, V. Robinson, H.G. Hollberg, L. Kitching, J. Atomic vapor cells for Chip-Scale atomic clocks with improved Long-Term frequency stability. Opt. Lett. 2005, 30, 2351–2353.
[12] Guo, H. Crossley, P. Design of a time synchronization system based on GPS and IEEE 1588 for transmission substations. IEEE Trans. Power Deliv. 2016, 32, 2091–2100.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Academic Journal of Science and Technology

This work is licensed under a Creative Commons Attribution 4.0 International License.








