Research Progress of Shear Wave Elastography in Musculoskeletal Diseases: Technical Principles and Clinical Applications
DOI:
https://doi.org/10.54097/pwgkdg96Keywords:
Shear wave elastic imaging; Musculoskeletal disease; Biomechanics; Quantitative diagnosis; Rehabilitation assessment.Abstract
In this paper, Shear Wave Elastography (SWE) technology and related literature in recent years are reviewed, and the research progress of SWE in musculoskeletal (MSK) diseases is reviewed, including the technical principle of SWE and its clinical application in MSK diseases. At present, SWE is widely used in the diagnosis of MSK-related diseases, with unique advantages such as non-invasive, real-time dynamic evaluation, and high spatial resolution, which can capture the mechanical changes of muscles, tendons, ligaments and other tissues at rest or under load, providing an objective basis for early diagnosis of diseases, efficacy monitoring and rehabilitation evaluation. However, as a new elastic imaging detection technology, SWE still needs to be further strengthened in the field of MSK disease research in the future, so as to further enhance the accuracy of SWE diagnosis, expand the scope of disease diagnosis, establish musculoskeletal SWE diagnostic criteria, standardize the operating process, and reduce cross-platform measurement errors.
Downloads
References
[1] Nagel J, Wegener F, Grim C, Hoppe MW. Effects of Digital Physical Health Exercises on Musculoskeletal Diseases: Systematic Review With Best-Evidence Synthesis. JMIR Mhealth Uhealth. 2024 Jan 23;12:e50616.
[2] Guan SY, Zheng JX, Sam NB, Xu S, Shuai Z, Pan F. Global burden and risk factors of musculoskeletal disorders among adolescents and young adults in 204 countries and territories, 1990-2019. Autoimmun Rev. 2023 Aug;22(8):103361.
[3] Briggs AM, Jordan JE, Kopansky-Giles D, Sharma S, March L, Schneider CH, Mishrra S, Young JJ, Slater H. The need for adaptable global guidance in health systems strengthening for musculoskeletal health: a qualitative study of international key informants. Glob Health Res Policy. 2021 May 28;6(1):24.
[4] Retzky JS, Koff MF, Nwawka OK, Rodeo SA. Novel Noninvasive Imaging Techniques to Assess Structural, Functional, and Material Properties of Tendon, Ligament, and Cartilage: A Narrative Review of Current Concepts. Orthop J Sports Med. 2025 Feb 18;13(2):23259671251317223.
[5] Roots J, Trajano GS, Fontanarosa D. Ultrasound elastography in the assessment of post-stroke muscle stiffness: a systematic review. Insights Imaging. 2022 Apr 5;13(1):67.
[6] Kopecká B, Ravnik D, Jelen K, Bittner V. Objective Methods of Muscle Tone Diagnosis and Their Application-A Critical Review. Sensors (Basel). 2023 Aug 15;23(16):7189.
[7] Abboud Y, Gaddam S. The Role of Endoscopic Ultrasound-Guided Shear Wave Elastography in Pancreatic Diseases. Diagnostics (Basel). 2024 Oct 19;14(20):2329.
[8] Althoff AD, Vance K, Plain M, Reeves RA, Pierce J, Gwathmey FW, Werner BC. Evaluation of Achilles Tendon Stiffness as Measured by Shear Wave Elastography in Female College Athletes Compared With Nonathletes. Sports Health. 2024 Jan-Feb;16(1):12-18.
[9] Qiang B, Xu Q, Hu A, Fang J, Shen C, Zhang Y, Wang J. Feasibility of shear wave elastography for evaluating lens stiffness in patients with age-related cataracts: A quantitative analysis. Heliyon. 2024 May 31;10(11):e32255.
[10] Hao Zhenmin, Deng Yuguang, Guo Zhenning, Wu Dongqian, Zhang Shengnan. Correlation between shear wave elastography quantitative parameters and non-specific low back pain and functional impairment at different disease stages. Chinese Journal of Clinical Imaging, 2025, 36 (01): 56-60.
[11] Haueise A, Le Sant G, Eisele-Metzger A, Dieterich AV. Is musculoskeletal pain associated with increased muscle stiffness? Evidence map and critical appraisal of muscle measurements using shear wave elastography. Clin Physiol Funct Imaging. 2024 May;44(3):187-204.
[12] Linke WA. Stretching the story of titin and muscle function. J Biomech. 2023 May;152:111553.
[13] Eisner LE, Rosario R, Andarawis-Puri N, Arruda EM. The Role of the Non-Collagenous Extracellular Matrix in Tendon and Ligament Mechanical Behavior: A Review. J Biomech Eng. 2022 May 1;144(5):050801.
[14] Ekstrand J, Bengtsson H, Waldén M, Davison M, Khan KM, Hägglund M. Hamstring injury rates have increased during recent seasons and now constitute 24% of all injuries in men's professional football: the UEFA Elite Club Injury Study from 2001/02 to 2021/22. Br J Sports Med. 2022 Dec 6;57(5):292–8.
[15] Kellis E, Kekelekis A, Drakonaki EE. Thoracolumbar Fascia and Lumbar Muscle Stiffness in Athletes with A History of Hamstring Injury. J Sports Sci Med. 2024 Jun 1;23(2):436-444.
[16] Lin CW, Shieh JY, Tsui PH, Chen CL, Lu CH, Hung YH, Lee HY, Weng WC, Gau SS. Acoustic radiation force impulse shear wave elastography quantifies upper limb muscle in patients with Duchenne muscular dystrophy. Ultrason Sonochem. 2023 Dec;101:106661.
[17] Sepúlveda-Loyola W, Osadnik C, Phu S, Morita AA, Duque G, Probst VS. Diagnosis, prevalence, and clinical impact of sarcopenia in COPD: a systematic review and meta-analysis. J Cachexia Sarcopenia Muscle. 2020 Oct;11(5):1164-1176.
[18] Deng M, Zhou X, Li Y, Yin Y, Liang C, Zhang Q, Lu J, Wang M, Wang Y, Sun Y, Li R, Yan L, Wang Q, Hou G. Ultrasonic Elastography of the Rectus Femoris, a Potential Tool to Predict Sarcopenia in Patients With Chronic Obstructive Pulmonary Disease. Front Physiol. 2022 Jan 5;12:783421.
[19] Yun SJ, Jin W, Cho NS, Ryu KN, Yoon YC, Cha JG, Park JS, Park SY, Choi NY. Shear-Wave and Strain Ultrasound Elastography of the Supraspinatus and Infraspinatus Tendons in Patients with Idiopathic Adhesive Capsulitis of the Shoulder: A Prospective Case-Control Study. Korean J Radiol. 2019 Jul;20(7):1176-1185.
[20] Wada T, Itoigawa Y, Yoshida K, Kawasaki T, Maruyama Y, Kaneko K. Increased Stiffness of Rotator Cuff Tendons in Frozen Shoulder on Shear Wave Elastography. J Ultrasound Med. 2020 Jan;39(1):89-97.
[21] Bartolotta TV, Orlando AAM, Dimarco M, Zarcaro C, Ferraro F, Cirino A, Matranga D, Vieni S, Cabibi D. Diagnostic performance of 2D-shear wave elastography in the diagnosis of breast cancer: a clinical appraisal of cutoff values. Radiol Med. 2022 Nov;127(11):1209-1220.
[22] Wu Hui, Sheng Qiumin, Zhu Jianfang. Shear Wave Elastography in Diagnosis of Peripheral Neuropathy in Rheumatoid Arthritis. Chinese Journal of Medical Imaging,20,28(6):456-460.
[23] Neto T, Freitas SR, Andrade RJ, Vaz JR, Mendes B, Firmino T, Bruno PM, Nordez A, Oliveira R. Noninvasive Measurement of Sciatic Nerve Stiffness in Patients With Chronic Low Back Related Leg Pain Using Shear Wave Elastography. J Ultrasound Med. 2019 Jan;38(1):157-164.
[24] Yang Beibei, Liu Lihong, Yu Shoujun, Liu Zhongfeng,Yin Weihong,SunYanhua.Analysis of the Diagnostic Value of Shear Wave Elastography in Alcoholic Peripheral Neuropathy.Chinese Journal of Ultrasound Medicine 37. 09 (2021): 1057-1060.
[25] Şahan MH, Doğan A, İnal M, Alpua M, Asal N. Evaluation of the Optic Nerve by Strain and Shear Wave Elastography in Patients With Migraine. J Ultrasound Med. 2019 May;38(5):1153-1161.
[26] Moran L, Royuela A, de Vargas AP, Lopez A, Cepeda Y, Martinelli G. Carpal Tunnel Syndrome: Diagnostic Usefulness of Ultrasound Measurement of the Median Nerve Area and Quantitative Elastographic Measurement of the Median Nerve Stiffness. J Ultrasound Med. 2020 Feb;39(2):331-339.
[27] Yoshikawa T, Inui A, Mifune Y, Nishimoto H, Yamaura K, Mukohara S, Shinohara I, Hoshino Y, Matsuishita T, Kuroda R. Assessment of the Ulnar Collateral Ligament of the Elbow Using Ultrasonic Shear Wave Elastography in Professional Baseball Players. Orthop J Sports Med. 2022 Dec 13;10(12):23259671221138134.
[28] Wu J, Qian Z, Liang W, Liu J, Ren L, Ren L. In vivo assessment of material properties of muscles and connective tissues around the knee joint based on shear wave elastography. J Mech Behav Biomed Mater. 2020 Sep;109:103829.
[29] Rougereau G, Marty-Diloy T, Vigan M, Donadieu K, Hardy A, Vialle R, Langlais T. Anatomical and biomechanical study of the inferior extensor retinaculum by shear-wave elastography in healthy adults. Surg Radiol Anat. 2022 Feb;44(2):245-252.
[30] Rougereau G, Marty-Diloy T, Vigan M, Donadieu K, Vialle R, Langlais T, Hardy A. Biomechanical evaluation of the anterior talo-fibular and calcaneo-fibular ligaments using shear wave elastography in young healthy adults. Orthop Traumatol Surg Res. 2024 Feb;110(1):103647.
[31] Gürün E, Aksakal M, Akdulum İ. Measuring stiffness of normal medial collateral ligament in healthy volunteers via shear wave elastography. Surg Radiol Anat. 2021 Oct;43(10):1673-1679.
[32] Pasurka M, Falck T, Kubach J, Simon M, Söllner S, Strobel D, Perl M, Betsch M. Comparison of In Vivo Stiffness of Tendons Commonly Used for Anterior Cruciate Ligament Reconstruction - A Shear Wave Elastography Study. Acad Radiol. 2024 Aug;31(8):3297-3305.
[33] Santilli G, Ciccarelli A, Martino M, Pacini P, Agostini F, Bernetti A, Giuliani L, Del Gaudio G, Mangone M, Colonna V, Vetrano M, Vulpiani MC, Stella G, Taurone S, Vigevano F, Cantisani V, Paoloni M, Fiore P, Gimigliano F. Pain, Function, and Elastosonographic Assessment After Shockwave Therapy in Non-Calcific Supraspinatus Tendinopathy: A Retrospective Observational Study. J Funct Morphol Kinesiol. 2025 Jan 21;10(1):39.
[34] Albano D, Basile M, Gitto S, Messina C, Longo S, Fusco S, Snoj Z, Gianola S, Bargeri S, Castellini G, Sconfienza LM. Shear-wave elastography for the evaluation of tendinopathies: a systematic review and meta-analysis. Radiol Med. 2024 Jan;129(1):107-117.
[35] Jeong JY, Khil EK, Kim AY, Lee SA, Choi JA. Utility of Preoperative Shear-Wave Elastography of the Supraspinatus Muscle for Predicting Successful Rotator Cuff Repair: A Prospective Observational Study With MRI Correlation. AJR Am J Roentgenol. 2022 Jun;218(6):1051-1060. doi: 10.2214/AJR.21.27129. Epub 2022 Jan 19. Erratum in: AJR Am J Roentgenol. 2022 Jun;218(6):1112.
[36] Fenwick A, Reichel T, Eden L, Schmalzl J, Meffert R, Plumhoff P, Gilbert F. Deltoid Muscle Tension Alterations Post Reverse Shoulder Arthroplasty: An Investigation Using Shear Wave Elastography. J Clin Med. 2023 Sep 25;12(19):6184.
[37] Zheng Zhi. Progress in clinical application of shear-wave elastography. Journal of Qiqihar Medical College 44. 12 (2023): 1166-1170.
[38] Miller T, Ying M, Sau Lan Tsang C, Huang M, Pang MYC. Reliability and Validity of Ultrasound Elastography for Evaluating Muscle Stiffness in Neurological Populations: A Systematic Review and Meta-Analysis. Phys Ther. 2021 Jan 4;101(1):pzaa188.
[39] Dang Wenzhu, Tong Minghui.Progress in the application of shear wave elastography in peripheral neuropathy[J].Journal of Medical Imaging 32.01 (2022): 164-166.
[40] Lin Xiaojun, LI Zhenzhou, Wang Huifang. Progress of shear wave elastography in detection of musculoskeletal system[J].Journal of Clinical Ultrasound Medicine 20. 12 (2018): 835-837.
[41] Liu Boji, Xu Huixiong. Application of shear wave elastography in biomechanical quantitative evaluation of muscle, tendon,and peripheral neuropathy[J]. Oncology Imaging 31. 01 (2022): 11-15.
[42] Seliverstova E, Caenen A, Bézy S, Nooijens S, Voigt JU, D’hooge J. Comparing Myocardial Shear Wave Propagation Velocity Estimation Methods Based on Tissue Displacement, Velocity and Acceleration Data. Ultrasound Med Biol. 2022 Nov;48(11):2207-2216.
[43] Shao Meng. Improvement of shear wave velocity measurement method in ultrasonic elastography. 2019. MA thesis, Shenzhen University.
[44] Cipriano KJ, Wickstrom J, Glicksman M, Hirth L, Farrell M, Livinski AA, Esfahani SA, Maldonado RJ, Astrow J, Berrigan WA, Piergies AMH, Hobson-Webb LD, Alter KE. A scoping review of methods used in musculoskeletal soft tissue and nerve shear wave elastography studies. Clin Neurophysiol. 2022 Aug;140:181-195.
[45] Zakrzewski J, Zakrzewska K, Pluta K, Nowak O, Miłoszewska-Paluch A. Ultrasound elastography in the evaluation of peripheral neuropathies: a systematic review of the literature. Pol J Radiol. 2019 Dec 21;84:e581-e591.
[46] Ruan Jian. Research status of shear wave elastography in musculosketetal system. Youjiang Medical Science 49. 02 (2021): 150-153.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Academic Journal of Science and Technology

This work is licensed under a Creative Commons Attribution 4.0 International License.








