Inter-turn Short Circuit Fault Diagnosis for PMSMs Based on a Novel Search Coil
DOI:
https://doi.org/10.54097/15362e37Keywords:
Permanent magnet synchronous motor, Inter-turn short-circuit fault, Search coil, Finite element.Abstract
Permanent magnet synchronous motors (PMSMs) may suffer from inter-turn short-circuit faults (ISFs) during their operation, which brings great challenges to the fault diagnosis of PMSMs and results in insufficient research on ISF diagnosis. To solve this problem, this paper proposes a novel search coil (SC) arrangement method for ISF diagnosis of PMSM. With the proposed configuration of SCs, it only needs to be installed on specific stator teeth. Then, a mathematical model of SC is developed, which serves as a basis for future investigations into fault characteristics using the novel SCs. Furthermore, by examining the time-domain characteristics of the search coil group (SCG), the time-domain energy of the SCG voltage is proposed as a fault diagnostic indicator. The finite element method (FEM) and experiments validate the correctness and effectiveness of the proposed method.
Downloads
References
[1] Y. Qi, E. Bostanci, V. Gurusamy, et al. A Comprehensive Analysis of Short-Circuit Current Behavior in PMSM Interturn Short-Circuit Faults [J]. IEEE Transactions on Power Electronics, 2018, 33(12): 10784-10793.
[2] F. Huang et al. Demagnetization Fault Diagnosis of Permanent Magnet Synchronous Motors Using Magnetic Leakage Signals [J]. IEEE Transactions on Industrial Informatics, 2023, 19 (4): 6105-6116.
[3] L. Zezula, M. Kozovsky and P. Blaha. Diagnostics of Interturn Short Circuits in PMSMs With Online Fault Indicators Estimation [J]. IEEE Transactions on Industrial Electronics, 2024 71(11): 15001-15011.
[4] R. Hu, J. Wang, A. R. Mills, et al. Current-Residual-Based Stator Interturn Fault Detection in Permanent Magnet Machines [J]. IEEE Transactions on Industrial Electronics, 2021, 68(1): 59-69.
[5] K. H. Baruti, C. Li, F. Erturk, et al. Online Stator Inter-Turn Short Circuit Estimation and Fault Management in Permanent Magnet Motors [J]. IEEE Transactions on Energy Conversion, 2023 38(2): 1016-1027.
[6] S. Moon, H. Jeong, H. Lee, et al. Interturn Short Fault Diagnosis in a PMSM by Voltage and Current Residual Analysis With the Faulty Winding Model [J]. IEEE Transactions on Energy Conversion, 2018, 33(1): 190-198.
[7] V. Gurusamy, E. Bostanci, C. Li, et al. A Stray Magnetic Flux-Based Robust Diagnosis Method for Detection and Location of Interturn Short Circuit Fault in PMSM [J]. IEEE Transactions on Instrumentation and Measurement, 2021, 70: 1-11.
[8] Mazzoletti M. A, Bossio G. R, De Angelo C. H. Interturn short-circuit fault diagnosis in PMSM with partitioned stator windings [J]. IET Electric Power Applications, 2020, 14(12): 2301-2311.
[9] Zhang Xiaoke, Jiao Ningfei, Mao Shuai, et al. A Method for Estimating the Rotor Position of an Aviation Multistage Starter/Generator in Low-Speed Segment Based on Stator Direct Axis Current Point Sampling of the Exciter [J/OL]. Journal of Chinese Electrical Engineering, 2024.
[10] Zhao Jing, Guan Xiaoqing, Li Chenghai, et al. A Comprehensive Evaluation of Inter-Turn Short Circuit Faults in PMSM Used for Electric Vehicles [J]. IEEE Transactions on Intelligent Transportation Systems, 2021, 22(1): 611-621.
[11] He Yu-Ling, Xu Ming-Xing, Zhang Wen, et al. Impact of Stator Interturn Short Circuit Position on End Winding Vibration in Synchronous Generators [J]. IEEE Transactions on Energy Conversion, 2021, 36(2): 713-724.
[12] X. Liu, W. Miao, Q. Xu, et al., Inter-Turn Short-Circuit Fault Detection Approach for Permanent Magnet Synchronous Machines Through Stray Magnetic Field Sensing [J]. IEEE Sensors Journal, 2019, 19(18): 7844-7895.
[13] V. Gurusamy, E. Bostanci, C. Li, et al. A Stray Magnetic Flux-Based Robust Diagnosis Method for Detection and Location of Interturn Short Circuit Fault in PMSM [J].IEEE Transactions on Instrumentation and Measurement, 2021, 70: 1-11.
[14] G. Mirzaeva, K. Saadi. Advanced Diagnosis of Stator Turn-to-Turn Faults and Static Eccentricity in Induction Motors Based on Internal Flux Measurement [J]. IEEE Transactions on Industry Applications, 2018, 54(4): 3961-3970.
[15] Z. Chong, S. Huang, Y. Yang, et al. Inter-turn fault diagnosis of permanent magnet synchronous machine based on tooth magnetic flux analysis [J]. IET Electric Power Applications, 2018, 12(6): 837-844.
[16] T. Lee, K. Kim, J. Hur. Diagnosis technique using detection coil in BLDC motor with Interturn Fault [J]. IEEE Transactions on Magnetics, 2014, 50(2): 1-4.
[17] Chen Hao, Zhang Nan, Gao Caixia, et al. Method for Locating Short-Circuit Fault Short Circuit Loops in Permanent Magnet Synchronous Motors [J]. Journal of Electric Machines and Control, 2023, 27(3): 124-134.
[18] W. Huang, B. Du, T. Li, et al. Inter-turn Short-Circuit Fault Diagnosis of Interior Permanent Magnet Synchronous Motor for Electric Vehicle Based on Search Coil [J]. IEEE Transactions on Power Electronics, 2023, 38(2): 2506-2515.
[19] J. Zhao, X. Guan, C. Li, Q. Mou, et al. Comprehensive Evaluation of Inter-Turn Short Circuit Faults in PMSM Used for Electric Vehicles [J]. IEEE Transactions on Intelligent Transportation Systems, 2021, 22(1): 611-621.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Academic Journal of Science and Technology

This work is licensed under a Creative Commons Attribution 4.0 International License.








