Comparison of the Structure, Working Principle, Materials, Advantages, Disadvantages, and Performance of Four Generations of Glucose Biosensors

Authors

  • Zihan Liu

DOI:

https://doi.org/10.54097/awgrer64

Keywords:

Biosensor Glucose, Generation, Nanomaterials, Electron Transform

Abstract

This paper mainly introduced the history of development and applications of glucose biosensors. The article first explains the basic composition and principles of biosensors, focusing on the role of glucose oxidase in blood glucose detection. Subsequently the paper systematically sorted out the evolution of four generations of glucose biosensors: The first generation of sensors relied on oxygen and were susceptible to interference, resulting in insufficient accuracy of the final results; the second generation added artificial media to improve stability and response speed; the third generation enhanced specificity and accuracy by achieving direct electron transfer between enzymes and electrodes, but it was very complex; the latest fourth generation adopted an enzyme-free design, using metal nanoparticles as electrocatalysts, with high sensitivity, low cost and excellent stability, overcoming limitations such as enzyme degradation.

Downloads

Download data is not yet available.

References

[1] A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors Sensors 2021, 21, 1109.https://doiorg/10.3390/s21041109

[2] Bhalla, N.; Jolly, P.; Formisano, N.; Estrela, P. Introduction to biosensors. Essays Biochem. 2016, 60, 1–8.

[3] Clark, L.C. & Lyons, C. (1962). Electrode systems for continuous monitoring in cardiovascular surgery. Annals of the New York Academy of Sciences, 102(1), 29–45.

[4] Clemens, A.H.; Chang, P.H.; Myers, R.W. Le développement d’un système automatique d’infusion d’insuline controle par laglycemie, son système de dosage du glucose et ses algorithmes de controle. Journ. Annu. Diabétol. Hotel Dieu 1976, 269–278.

[5] Clemens, A.H.; Chang, P.H.; Myers, R.W. The development of biostator, a glucose controller insulin infusion system (GCIIS). Horm. Metab. Res. Suppl. 1977, 7, 22–23.

[6] Geyssant, A.; Dormois, D.; Barthelemy, J.C.; Lacour, J.R. Lactate determination with the lactate analyser LA 640: A critical study.Scand. J. Clin. Lab. Investig. 1985, 45, 145–149.

[7] Heineman, W.R.; Jensen, W.B. Leland C. Clark Jr. (1918–2005). Biosens. Bioelectron. 2006, 21, 1403–1404.

[8] Clark, L.C.; Lyons, C. Electrode systems for continuous monitoring in cardiovascular surgery. Ann. N. Y. Acad. Sci. 1962, 102, 29–45.

[9] Wang, J. (2008). Electrochemical glucose biosensors. Chemical Reviews, 108(2), 814–825. https:// doi. org/10.1021/cr068123a

[10] Suzuki, K., Shiroishi, H., Yoshida, M., & Sode, K. (2020). Engineered glucose oxidase capable of quasi-direct electron transfer. International Journal of Molecular Sciences, 21(3), 1137. https:// doi.org/ 10. 3390/ ijms21031137

[11] Amiripour, F.P.; Ghasemi, S.; Azizi, S.N. A novel non-enzymatic glucose sensor based on gold-nickel bimetallic nanoparticles doped aluminosilicate framework prepared from agro-waste material. Appl. Surf. Sci. 2021, 537, 147827.

Downloads

Published

26-11-2025

Issue

Section

Articles