Research on Structural Performance Analysis of Agricultural Greenhouses Based on ANSYS

Authors

  • Xin Wang Sichuan University of Science & Engineering, Yibin 644000, China
  • Guangzhong Hu Sichuan University of Science & Engineering, Yibin 644000, China
  • Ping Wang Sichuan University of Science & Engineering, Yibin 644000, China
  • Jialei Zhang Sichuan University of Science & Engineering, Yibin 644000, China
  • Hao Luo Sichuan University of Science & Engineering, Yibin 644000, China
  • Fugen Luo
  • Anying Cai Sichuan University of Science & Engineering, Yibin 644000, China

DOI:

https://doi.org/10.54097/twy66f68

Keywords:

Agricultural greenhouse; Frame structure; Cross-section shape; Finite element analysis; Wind and snow loads.

Abstract

To investigate the effects of different cross- section shapes on the mechanical properties ofagricultural greenhouse frame structures, static analysis of a single‑span agricultural greenhouse frame under wind and snow loads was carried out. Firstly, wind and snow loads were calculated. Secondly, with identical material parameters, boundary conditions and load cases, four combinations of arch tube and longitudinal beam cross‑section shapes were designed, and three‑dimensional models were established for finite element analysis. Finally, the deformation, stress and stability of structures under snow and wind loads were comparatively studied.the results show that under snow load, the maximum displacement and maximum equivalent stress of the frame with elliptical arch tubes and elliptical longitudinal beams are reduced by 11.876 mm and 103.18 MPa respectively compared with the frame of circular arch tubes and circular longitudinal beams; the maximum displacement decreases by 39 % and the maximum equivalent stress decreases by 25.8 %. Under wind load, its maximum displacement is reduced by 14.688 mm, with an overall reduction of 30.2 %. The greenhouse skeleton adopting the combined cross‑section of elliptical arch tubes and elliptical longitudinal beams can effectively improve the performance and safety of agricultural greenhouses.

Downloads

Download data is not yet available.

References

[1] Ministry of Housing and Urban-Rural Development of the People’s Republic of China. (2022). Standard for design of agricultural greenhouse structures: GB/T 51424-2022. China Planning Press.

[2] Yu, Y. H., Wang, J. P., & Ying, Y. B. (2007). Nonlinear finite element analysis on ultimate bearing capacity of arch structure of plastic greenhouse under snow load. Transactions of the Chinese Society of Agricultural Engineering, 23(3), 158–162.

[3] Qie, L. J., Yin, Q. Z., & Han, J. H. (2019). Structural design and finite element analysis of double-arch, multi-span and double-film plastic greenhouse. Journal of Chinese Agricultural Mechanization, 40(11), 55–59.

[4] Xiang, B. T., Guo, H., Wang, J. L., et al. (2024). Structural stability and parametric analysis of section steel arch frame for solar greenhouse. Transactions of the Chinese Society of Agricultural Engineering, 40(13), 196–204.

[5] Wang, C., Lu, J. R., Lin, Y. F., et al. (2025). Wind-induced vibration response and wind vibration coefficient of plastic greenhouses. Acta Agriculturae Zhejiangensis, 37(9), 1981–1990.

[6] Qiao, H. Y., Lan, T., Ding, M., et al. (2021). Study on ultimate bearing capacity of T-type clamp joint in steel greenhouse. Industrial Construction, 51(3), 115–120. https://doi.org/10.13204/j.gyjzg20051508

[7] Ren, J. (2024). Structural analysis of plastic greenhouse in Shanghai based on ANSYS. Science and Technology & Innovation, 12, 78–80, 86. https://doi.org/10.15913/j.cnki.kjycx.2024.12.021

[8] Zhang, T. H., & Zhong, J. L. (2023). Wind and snow load calculation and structural optimization of agricultural greenhouses. Journal of Beijing Information Science and Technology University(Natural Science Edition), 38(6), 64–69. https://doi.org/10.16508/j.cnki.11-5866/n.2023.06.009

[9] Dong, X., Piao, F., Du, N., Dong, H., Zhang, T., Qin, Y., Li, Y., & Guo, Z. (2025). Optimization of structural configuration and ridge height for large-span insulated plastic greenhouse based on finite element analysis. Agriculture, 15(13), 1333. https://doi.org/10.3390/agriculture15131333 DOI: https://doi.org/10.3390/agriculture15131333

[10] Wang, Y., An, Y. E., An, X. X., et al. (2024). Structural design practice and innovation of multi-span photovoltaic vegetable greenhouse. Agricultural Development & Equipments, 6, 104–106.

[11] Wang, C. J., Zhu, J. C., Hu, B. G., et al. (2025). Structural stress analysis of portal greenhouse. Enterprise Science and Technology & Development, 8, 77–82. https://doi.org/10.20137/j.qykjyfz.45-1359/t.20250810.077

[12] Li, Y., Fan, Y. P., & Wang, Y. (2020). Research on structural optimization design of multi-span film greenhouse. Modern Manufacturing Technology and Equipment, 2, 52–53. https://doi.org/10.16107/j.cnki.mmte.2020.0126

[13] Gong, W., Liu, J., Yang, X. F., et al. (2017). Study on basic wind pressure value for structural design of greenhouse in Hainan. Agricultural Engineering Technology, 37(34), 44–51. https://doi.org/10.16815/j.cnki.11-5436/s.2017.34.007

[14] Zhang, H. M. (2024). Design and analysis of steel structure for large-span industrial workshop. Engineering Construction and Design, 14, 19–21.

[15] Wei, G., & Liu, B. H. (2025). Structural performance analysis of plastic greenhouse. Agricultural Engineering, 15(10), 53–58. https://doi.org/10.19998/j.cnki.2095-1795.202510010

[16] Jiang, Y. C., Bai, Y. K., Wang, Y. G., et al. (2018). Wind-induced vibration response law of plastic greenhouse. Journal of Huazhong Agricultural University, 37(5), 123–130.

[17] Xu, J., Hu, Z. K., Shi, Z. Q., et al. (2024). Dynamic response of wind-induced vibration of arch plastic greenhouse. Journal of China Agricultural University, 29(11), 188–195.

[18] Wang, C., Jiang, Y. C., Li, X. Y., et al. (2021). Wind-induced vibration response analysis of Chinese solar greenhouses. Computers and Electronics in Agriculture, 181, 105954. DOI: https://doi.org/10.1016/j.compag.2020.105954

[19] Shi, Y. N., Xie, H. Y., Zheng, X., et al. (2024). Experimental study on mechanical performance of truss arch plastic greenhouse frame under in-plane vertical load. Journal of Agricultural Mechanization Research, 46(3), 154–160. https://doi.org/10.13427/j.cnki.njyi.2024.03.007

[20] Ding, X. M., Zhou, C. J., Wei, X. M., et al. (2013). Analysis on design load and load combination of continuous plastic greenhouse structure. Transactions of the Chinese Society of Agricultural Engineering, 29(14), 187–193.

[21] Ministry of Housing and Urban-Rural Development of the People’s Republic of China, & General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China. (2012). Load code for the design of building structures: GB 50009—2012.