Single-Terminal Fault Location Method for HVDC Transmission Lines Based on Propagation-Aligned Interpolation Augmentation and Time–Frequency Gated Fusion
DOI:
https://doi.org/10.54097/n1cs3w21Keywords:
HVDC transmission; fault location; propagation-aligned interpolation augmentation; time–frequency feature fusion; gated network.Abstract
Aiming at the difficulty of accurately characterizing the mapping between single-terminal fault transients and fault distance in HVDC transmission lines, this paper proposes a fault location method based on propagation-aligned interpolation augmentation and a time–frequency gated fusion network, combining the propagation-delay differences induced by distance variation with the time–frequency features of transients. To alleviate the insufficient distance coverage of training samples and the inconsistent wavefront arrival times caused by direct interpolation, adjacent waveforms with the same fault type and transition resistance are aligned and interpolated according to propagation delays calibrated on the training set, and an augmented training set is constructed together with end-zone densification and source quality screening. To promote time–frequency feature fusion, a dual-branch time–frequency gated fusion network is built, in which a CNN–BiLSTM branch and a Conv1D–SE branch extract transient temporal features and S-transform magnitude-spectrum features respectively, and feature-wise gated fusion then performs fault distance regression. Experimental results show that the proposed method achieves a mean absolute error of 0.285 km and a P95 error of 0.752 km, reducing the mean absolute error by about 48.6% compared with the equal-budget linear interpolation augmentation configuration. The proposed method helps improve single-terminal fault location accuracy under the experimental conditions of this paper.
Downloads
References
[1] Lei, Z., Hao, L., Dai, J., et al. (2022). A review of fault location research for HVDC transmission lines. Power System Protection and Control, 50(11), 178–187. https://doi.org/10.19783/j.cnki.pspc.211228. (in Chinese)
[2] Suonan, J., Gao, S., Song, G., et al. (2010). A novel fault-location method for HVDC transmission lines. IEEE Transactions on Power Delivery, 25(2), 1203–1209. https://doi.org/10.1109/TPWRD.2009.2033078. DOI: https://doi.org/10.1109/TPWRD.2009.2033078
[3] Dardengo, V. P., Fardin, J. F., & De Almeida, M. C. (2021). Single-terminal fault location in HVDC lines with accurate wave velocity estimation. Electric Power Systems Research, 194, 107057. https://doi.org/10.1016/j.epsr.2021.107057. DOI: https://doi.org/10.1016/j.epsr.2021.107057
[4] Huai, Q., Liu, K., Hooshyar, A., et al. (2021). Single-ended line fault location method for multi-terminal HVDC system based on optimized variational mode decomposition. Electric Power Systems Research, 194, 107054. https://doi.org/10.1016/j.epsr.2021.107054. DOI: https://doi.org/10.1016/j.epsr.2021.107054
[5] Reis, R. L. A., Lopes, F. V., Neves, W. L. A., et al. (2021). An improved single-ended correlation-based fault location technique using traveling waves. International Journal of Electrical Power & Energy Systems, 132, 107167. https://doi.org/10.1016/j.ijepes.2021.107167. DOI: https://doi.org/10.1016/j.ijepes.2021.107167
[6] Hao, Y., Wang, Q., Li, Y., et al. (2018). An intelligent algorithm for fault location on VSC-HVDC system. International Journal of Electrical Power & Energy Systems, 94, 116–123. https://doi.org/10.1016/j.ijepes.2017.06.030. DOI: https://doi.org/10.1016/j.ijepes.2017.06.030
[7] Wang, L., He, Y., & Li, L. (2021). A single-terminal fault location method for HVDC transmission lines based on a hybrid deep network. Electronics, 10(3), 255. https://doi.org/10.3390/electronics10030255. DOI: https://doi.org/10.3390/electronics10030255
[8] Inwumoh, J., Baguley, C., Madawala, U., et al. (2023). A novel fault location strategy based on Bi-LSTM for MMC-HVDC systems. The Journal of Engineering, 2023(10), e12310. https://doi.org/10.1049/tje2.12310. DOI: https://doi.org/10.1049/tje2.12310
[9] Wang, X., Zhang, D., Li, M., et al. (2023). Fault location method for hybrid DC transmission systems based on wavelet energy spectrum and SSA-GRU. Power System Protection and Control, 51(12), 14–24. https://doi.org/10.19783/j.cnki.pspc.221509. (in Chinese)
[10] Su, C., Yang, Q., Wu, X., et al. (2023). A two-terminal fault location fusion model of transmission line based on CNN-Multi-Head-LSTM with an attention module. Energies, 16(4), 1827. https://doi.org/10.3390/en16041827. DOI: https://doi.org/10.3390/en16041827
[11] Tang, Y., Shu, H., Liu, H., et al. (2025). A pre-classification method of field-recorded traveling waves for online fault location based on CABFAM-Transformer. Transactions of China Electrotechnical Society, 40(5), 1455–1470. https://doi.org/10.19595/j.cnki.1000-6753.tces.240326. (in Chinese)
[12] Li, C., & He, P. (2018). Fault-location method for HVDC transmission lines based on phase frequency characteristics. IET Generation, Transmission & Distribution, 12(4), 912–916. https://doi.org/10.1049/iet-gtd.2017.0967. DOI: https://doi.org/10.1049/iet-gtd.2017.0967
[13] Zhang, H., Cisse, M., Dauphin, Y. N., et al. (2018). Mixup: Beyond empirical risk minimization. International Conference on Learning Representations. https://openreview.net/forum?id=r1Ddp1-Rb.
[14] Graves, A., & Schmidhuber, J. (2005). Framewise phoneme classification with bidirectional LSTM and other neural network architectures. Neural Networks, 18(5–6), 602–610. https://doi.org/10.1016/j.neunet.2005.06.042. DOI: https://doi.org/10.1016/j.neunet.2005.06.042
[15] Stockwell, R. G., Mansinha, L., & Lowe, R. P. (1996). Localization of the complex spectrum: The S transform. IEEE Transactions on Signal Processing, 44(4), 998–1001. https://doi.org/10.1109/78.492555. DOI: https://doi.org/10.1109/78.492555
[16] Hu, J., Shen, L., & Sun, G. (2018). Squeeze-and-excitation networks. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, 7132–7141. https://doi.org/10.1109/CVPR.2018.00745. DOI: https://doi.org/10.1109/CVPR.2018.00745
[17] Huber, P. J. (1964). Robust estimation of a location parameter. The Annals of Mathematical Statistics, 35(1), 73–101. https://doi.org/10.1214/aoms/1177703732. DOI: https://doi.org/10.1214/aoms/1177703732
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Academic Journal of Science and Technology

This work is licensed under a Creative Commons Attribution 4.0 International License.