Accurate Implantation and Long-term Stability with the Assistance of Computer-aided Design

Authors

  • Na Wang

DOI:

https://doi.org/10.54097/ijbls.v2i1.5224

Keywords:

Dental implant, Computer-aided design, Digital technique, Digital smile design

Abstract

With the constant development of radiation and computer technology, the field of implant dentistry is also experiencing a digital revolution, including digitalized data acquisition, computer-aided virtual planning, computer-guided implant surgery and restoration, etc. The digitalized clinical protocol promotes a more standardized and accurate dental implant treatment, which certainly will reduce the occurrence of complications for dental implant treatment, and achieve more predictable long-term stability in both function and aesthetics, This paper summarized the digital collection, digital smile design, computer-guided surgery planning, and implant supported prosthesis design in combined with the development status of digital technique, and the future trend.

Downloads

Download data is not yet available.

References

Xie L, Luo B, Zhong W. How are smallholder farmers involved in digital agriculture in developing countries: a case study from China[J]. Land, 2021, 10(3): 245.

Marghalani A,Weber HP,Finkelman M,et al.Digital ver- sus conventional implant impressions for partially edentulous arches:An evaluation of accuracy [J].J Prosthet Dent, 2018,119(4):574-579,

Lepidi L,Galli M,Grammatica A. et al.Indirect digital workflow for virtual cross-mounting of fixed implant-suppor- ted prostheses to create a 3D virtual patient[J].J Prosth- odont,2021.30(2):177-182.

Zheng F,Chee WW.Stereographic analog application in im plant-supported complete rehabilitation:A dental technique [J].J Prosthet Dent,2020,124(1):14-18.

Jankelson B.Swain CW,Crane PF,et al.Kinesiometric in- strumentation:a new technology[J].J Am Dent Assoe, 1975,90(4):834-840.

Wismeijer D. Joda T,Flügge T,et al,Group 5 ITI Consen- sus Report:Digital technologies[J],Clin Oral Implants Res, 2018,29 Suppl 16:436-442.

Kim RJ, Benic GI,Park JM.Trueness of digital intraoral impression in reproducing multiple implant position[J].PLoS One,2019,14(11):e0222070.

Kim KR,Seo KY,Kim S.Conventional open-tray impres- sion versus intraoral digital sean for implant-level complete arch impression[J],J Prosthet Dent,2019,122(6):543- 549.

Wellens HLL,Hoskens H,Claes P,et al. Three-dimension- al facial capture using a custom-built photogrammetry setup: Design,performance, and cost[J].Am J Orthod Dentofacial Orthop,2020,158(2):286-299.

Lane C.Harrell W Jr.Completing the 3-dimensional pieture [J].Am J Orthod Dentofacial Orthop,2008,133(4):612- 620.

Petrides G,Clark JR.Low H,et al. Three dimensional scanners for soft-tissue facial assessment in clinical practice [J].JPlast Reconstr Aesthet Surg,2021,74(3):605-614.

Weinberg SM,Kolar JC.Three-dimensional surface ima- ging:limitations and considerations from the anthropometric perspective[J].J Craniofac Surg,2005,16(5):847-851.

Bush K. Antonyshyn O.Three-dimensional facial anthro-pomnetry using a laser surface scanner: validation of the tech- nique[J].Plast Reconstr Surg,1996,98(2):226-235.

Meadows DM,Johnson WO,Allen JB.Generation of surface contours by moire patterns [J].Appl Opt,1970,9(4):942- 947.

Artopoulos A,Buytaert JA,Dirckx JJ,et al.Comparison of the accuracy of digital stereophotogrammetry and projection moiréprofilometry for three dimensional imaging of the face[J].Int J Oral Maxillofac Surg,2014,43(5):654-662.

Deli R, Galantucci LM,Laino A, et al. Three dimensional methodology for photogrammetric acquisition of the soft tis- sues of the face; a new clinical-instrumental protocol[J]. Prog Orthod,2013,14:32.

Lubbers HT,Medinger L,Kruse A,et al.Precision and ac- curacy of the 3dMD photogrammetric system in craniomaxil- lofacial application[J],J Craniofac Surg, 2010,21(3):763- 767.

Tzou CH,Artner NM,Pona I,et al. Comparison of three dimensional surface-imaging systems[J].J Plast Reconstr Aesthet Surg, 2014,67(4):489-497.

Hicks ST,Wood DP. Recording condylar movement with two facebow systems[J],Angle Orthod,1996.66(4):293- 300.

Hobo S. Mochizuki S. A kinematic investigation of mandibu- lar border movement by means of an electronic measuring system.Part I:Development of the measuring system[J].J Prosthet Dent,1983,50(3):368-373.

Hobo S. A kinematic investigation of mandibular border movement by means of an electronic measuring system.Part I:Rotational center of lateral movement[J].J Prosthet Dent,1984,52(1):66-72.

Cordray FE. Articulated dental cast analysis of asymptomatie and symptomatic populations[J].Int J Oral Sci,2016,8(2): 126-132.

Bock A, Peters F, Winnand P, et al. One year of COVID-19 pandemic: a cross sectional study on teaching oral and maxillofacial surgery[J]. Head & Face Medicine, 2021, 17(1): 1-7.

Meereis CT,de Souza GB,Albino LG,et al.Digital smile design for computer assisted esthetic rehabilitation:two-year follow-up[J].Oper Dent,2016,41(1):E13-E22.

Faloye B O, Adeoluwa B M, Adeosun O M. Digitalization, film production and global education dynamism: A study of Pre-Service teachers’ speech proficiency[J]. Global Journal of Arts, Humanities and Social Sciences, 2021, 9(6): 82-91.

Mora MA,Chenin DL,Arce RM. Software tools and surgi- cal guides in dental-implant-guided surgery[J].Dent Clin North Am,2014,58(3):597-626.

Cristache CM.Gurbanescu S. Accuracy evaluation of a stere- olithographic surgical template for dental implant insertion u- sing 3D superimposition protocol[J].Int J Dent,2017,2017: 4292081.

Lops D. Meneghello R.Sbricoli L,et al. Precision of the connection between implant and standard or computer-aided design/computer-aided manufacturing abutments:a novel e-valuation method[J].Int J Oral Maxillofac Implants,2018, 33(1):23-30.

Sumi T,Braian M,Shimada A,et al.Characteristics of im- plant-CAD/CAM abutment connections of two different in- ternal connection systems[J].JOral Rehabil,2012,39(5): 391-398.

Hamed MT,Abdullah Mously H,Khalid Alamoudi S.et al. A systematic review of screw versus cement-retained fixed implant supported reconstructions[J].Clin Cosmet Investig Dent.2020,12:9-16.

Toledano M, Toledano-Osorio M, Carrasco-Carmona Á, et al. State of the art on biomaterials for soft tissue augmentation in the oral cavity. part II: synthetic polymers-based biomaterials[J]. Polymers, 2020, 12(8): 1845.

Jia P.Yang J,Yue Z,et al. Comparison of peri-implant sub- mucosal microbiota in arches with zirconia or titanium im- plant-supported fixed complete dental prostheses; a study protocol for a randomized controlled trial[J].Trials,2020. 21(1):979.

Storelli S,Del Fabbro M. Implant supported cantilevered fixed dental rehabilitations in partially edentulous patients: Systematic review of the literature.Part I[J].Clin Oral Im- plants Res,2018,29 Suppl 18:253-274.

Downloads

Published

14-02-2023

Issue

Section

Articles

How to Cite

Wang, N. (2023). Accurate Implantation and Long-term Stability with the Assistance of Computer-aided Design. International Journal of Biology and Life Sciences, 2(1), 28-31. https://doi.org/10.54097/ijbls.v2i1.5224