Feature Extraction of Transient Zero-Sequence Voltage and Adaptive Protection Criterion for High-Resistance Ground Faults in Low-Voltage Distribution Networks
DOI:
https://doi.org/10.54097/7qr7q687Keywords:
Low-Voltage Distribution Network, High-Resistivity Grounding Fault, Transient Zero-Sequence Voltage, Feature Extraction, Adaptive Protection CriterionAbstract
High-resistance ground faults (HRGFs) in low-voltage distribution networks are highly concealed. Traditional zero-sequence current protection and overvoltage protection are prone to failure to operate or maloperation, making it difficult to meet the requirements of safe power supply. This paper aims to improve the sensitivity and adaptability of HRGF detection by optimizing feature extraction methods and constructing adaptive protection criteria through in-depth analysis of transient zero-sequence voltage signals. The study employs signal preprocessing techniques such as wavelet denoising and adaptive filtering, combined with multi-dimensional feature extraction algorithms in the time domain, frequency domain, and time-frequency domain, and designs an adaptive threshold adjustment mechanism based on real-time operating conditions. Through MATLAB/Simulink simulation and laboratory experiments, the proposed method achieves an HRGF detection accuracy of 98.7% within the fault resistance range of 500Ω~5000Ω, with an action time of less than 20ms. This effectively solves the problem of insufficient sensitivity of traditional protection schemes for high-resistance faults and provides reliable technical support for HRGF protection in low-voltage distribution networks.
Downloads
References
[1] Qin, S. Y., Xue, Y. D., Liu, L. Z., Guo, Y. H., & Xu, M. M. (2022). Transient characteristics and impact analysis of small current grounding faults in active distribution networks. Journal of Electrical Engineering, 37(3), 655–666.
[2] Wang, L. F., Li, R., Shang, X. Y., Li, Q. X., & Qiu, Z. J. (2025). Construction of a gene library of operating condition characteristics of distribution network lines based on wavelet entropy. Electrical Engineering, 26(2), 35–41.
[3] Li, J., He, M., Huang, S. D., Liu, J., & Liu, Z. Y. (2024). Grounding fault protection algorithm for small resistance grounding active distribution networks based on phase difference. Journal of Electrical Engineering, 39(23), 7418–7429.
[4] Deng, F., Mei, L. J., Tang, X., Xu, F., & Zeng, X. J. (2021). A method for fault location in distribution networks based on time-frequency domain traveling wave panoramic waveform. Journal of Electrical Engineering, 36(13), 2861–2870.
[5] Li, Z. F., Guo, X. F., Fan, M., Xia, J. L., & Dong, X. (2022). A method for identifying single-phase grounding fault types based on fusion model. Journal of Chongqing University, 45(9), 61–72.
[6] Wang, K. X., Shao, Y., Wang, L. M., & Zhou, H. (2022). A review of research on single-phase grounding fault location methods in ship power grids. Ship Electronic Engineering, 42(8), 135–140.
[7] Luo, G. M., Tan, Y. J., Wu, M. Y., He, J. H., & Tang, P. Z. (2025). Power differential protection of active distribution networks considering voltage drop differences. Journal of Electrical Engineering, 40(4), 1287–1306.
[8] Wu, Y. Q., Li, Z. T., Lin, X. N., Huang, Z. X., & Li, Z. (2024). A method for selecting line-mode traveling waves in distribution networks based on the boundary characteristics of high-frequency filtering in substations. Journal of Electrical Engineering, 39(7), 2072–2088.
[9] Tang, Y. T., Shu, H. C., Liu, H. M., Su, X., Han, Y. M., & Dai, Y. (2025). A method for pre-classification of traveling waves measured in online ranging of transmission lines based on CABFAM-Transformer. Journal of Electrical Engineering, 40(5), 1455–1470.