Intelligent Fire Resistance Testing and Calculation of Precast Modular House by Computer Numerical Simulation
DOI:
https://doi.org/10.54097/hset.v23i.3619Keywords:
precast, full-scale, flat-packed modular house, fire resistance test.Abstract
Through the fire resistance tests of fourteen components and one full-scale flat-packed modular house, the fire resistance limits of both steel components under standard fire curve and modular house entirety under real fire were studied. Test results showed that the fire safety could be guaranteed for applying light steel modular houses in low-rise buildings. In addition to structural fire protection design, fire performance simulation should also be combined with the measures of smoke alarm, spray, smoke diffusion simulation, evacuation simulation, fuel control and rescue response to ensure the fire safety. The research results of this paper can provide references for fire protection design of light steel modular houses.
Downloads
References
Liu J.D., Experimental research on joint of steel module and fire resistance of components [D]. Tianjin University,2017.
Wang N., Huang Y.S., Huang D.J., Modularization - the way to develop building industrialization [J]. Construction and Architecture, 2015(09): 6-13.
Ding Y., Deng E.F., Zong L., etc., “State-of-the-art on connection in modular steel construction”, Journal of Building Structures, 40(3), 33-40, 2019.
Li C.T., Wen X.Y., Shuai Y.Y., etc., “Application of modular steel structure building in emergency hospital for infectious diseases”, Journal of BEE, 49(7), 133-139, 2021.
Peng L.L., Xie H., Yuan L.L., etc., Application of Fabricated Building Design in Wuhan Leishenshan Hospital [J]. Huazhong Architecture, 2020, 38(04): 71-77.
Du Z.J., Zhang J.B., Architectural Design of Prefabricated Infectious Disease Hospitals to Meet the Urgent Need [J]. Chinese Hospital Architecture & Equipment, 2020, 21(06): 25-28.
Liu. F., Application of prefabricated modular building in national emergency management system [J]. China Construction Metal Structure, 2020(05): 67-69.
Li B., “Discussion on fire protection design of modular building”, Journal of Chinese People’s Armed Police Force Academy, 29(6), 49-51, 2013.
Chen Y., Zhou Y.A., Wen X.Y., etc., “Fire Resistance test of modular steel structure floor in European standard system”, Proceedings of 2020 Industrial Architecture Academic Conference (Last Volume), Beijing, China, 342-346, 2020.
Code for fire protection design of buildings (GB 50016-2014).
Fire-resistance tests Elements of building construction (GB/T 9978-2008).
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.