Study on Graphene-modified FRP Bars Used in the Process of Construction Health Management
DOI:
https://doi.org/10.54097/fbem.v2i2.173Keywords:
BFRP bars, Construction management, Fatigue test, Graphene-modificationAbstract
The distributed long-gauge optical sensor on fiber reinforced polymer (FRP) bar cannot be manufactured through integrated production in current situation, which is hard for construction management. On the other hand, the point-sensing technology of the self-sensing bar will cause deviations in structural health monitoring (SHM). To solve these issues, applying the graphene/epoxy on FRP members is a feasible method for the piezoresistive characteristics of graphene. In this paper, basalt FRP (BFRP) bars with graphene/epoxy film were tested under repeated and cyclic loads and the resistance was measured at the same time until they were broken down. The results suggested that the test pieces can maintain stable sensing performance under repeated and cyclic loads. These facts indicated that the graphene-modified BFRP bars can well reflect the stress condition of the structural member within a safe range and can maintain stable self-sensing performance in the construction health management.
Downloads
References
WANG X, SHI J Z, WU Z S. et al. Fatigue behavior of basalt fiber-reinforced polymer tendons for prestressing applications [J]. Journal of composites for construction, 2015, 20(3): OO00649.
WANG X, SHI J Z, LIU J, et a1. Creep behavior of basalt fiber reinforced polymer tendons for prestressing application [J]. Materials and Design, 2014, 59(7): 558-564.
Hong W; Wu ZS, Yang CQ, et a1. Identification of modal macro—strain vector based on distributed long—gage FBG sensor under ambient vibration [C]. Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems, 2010, 7647, 7647: 36—44.
Li SZ, Wu ZS. A model—flee method for damage locating and quantifying in a beam—like structure based on dynamic distributed strain measurements [J]. Computer Aided Civil and Infrastructure Engineering, 2008, 23: 404-413.
Allen, M.J., Tung, V.C. and Kaner, R.B. (2010) Honeycomb Carbon: A Review of Graphene. Chemical Reviews, 110, 132-145.
Novoselov, K.S., Geim, A.K., Morozov, S.V., Jiang, D., Katsnelson, M.I., Grigorieva, I.V., Dubonos, S.V. and Firsov, A.A. (2005) Two-Dimensional Gas of Massless Dirac Fermions in Graphene. Nature, 438, 197-200.
Meyer, J.C., Geim, A.K., Katsnelson, M.I., et al. (2007) The Structure of Suspended Graphene Sheets. Nature, 446, 60-63.
GB 50608-2010. Technical code for infrastructure application of FRP composites. (in Chinese)
Feng Bo, Wang Xin, Wu ZhiShen. Fatigue lifr assessment of FRP cable for long-span cable-stayed bridge [J]. Composite Structures, 2019, 210:159-166.
Miner MA. Cumulative damage in fatigue. Journal of Applied Mechanics, 1945, 12(3): 159-164.