A Method of Dynamic Spatial Positioning of the Eyeball Based on Optic Disc Feature Following in Infants and Young Children

Authors

  • Mingjun Ju
  • Zhongmin Li
  • Jing Wang
  • Xiaohui Guo
  • Biao Hu

DOI:

https://doi.org/10.54097/vzyv2y61

Keywords:

Optic Papilla, Dynamic Spatial Positioning, Digital-analog Linkage, Visual Angle Distortion

Abstract

The dynamic spatial positioning of infants' eyes is crucial in ophthalmic retinal screening and medical imaging research. It plays an important role in the diagnosis of retinal diseases, the design of personalized treatment plans, and the monitoring of ophthalmic surgery. In order to solve the defects of existing eye tracking equipment and technology, such as complex implementation, sensitivity to environmental conditions, and limited long-term use, this study proposed a dynamic spatial positioning method of the eye based on the characteristics of the optic disc of infants. This method calibrates the size of the eye and retinal image through digital-analog linkage technology. It establishes a mapping relationship between pixels and physical sizes, and effectively solves the perspective distortion problem in retinal image acquisition, improving positioning accuracy and reliability. The centroid of the optic disc is selected as the reference point for spatial transformation, and the dynamic spatial changes of the eye are converted into changes in the centroid of the optic disc. Experimental results show that this method has good accuracy and robustness. The accuracy of dynamic spatial positioning of the eye is 0.0001 mm, and its average error is 0.000888 mm.

Downloads

Download data is not yet available.

References

[1] G Helveston E M, Krach D, Plager D A, et al. A new classification of superior oblique palsy based on congenital variations in the tendon[J]. Ophthalmology, 1992, 99(10): 1609-1615.

[2] Straumann D, Steffen H, Landau K, et al. Primary position and Listing’s law in acquired and congenital trochlear nerve palsy[J]. Investigative ophthalmology & visual science, 2003, 44(10): 4282-4292.

[3] Swami A U, Steinert R F, Osborne W E, et al. Rotational malposition during laser in situ keratomileusis[J]. American journal of ophthalmology, 2002, 133(4): 561-562.

[4] Chernyak D A. Cyclotorsional eye motion occurring between wavefront measurement and refractive surgery[J]. Journal of Cataract & Refractive Surgery, 2004, 30(3): 633-638.

[5] Müller P U, Cavegn D, d'Ydewalle G, et al. A comparison of a new limbus tracker, corneal reflection technique, Purkinje eye tracking and electro-oculography[J]. 1993.

[6] Ydewalle G, Rensbergen J V. Perception and cognition: Advances in eye movement research[J]. (No Title), 1993.

[7] Young L R, Sheena D. Survey of eye movement recording methods[J]. Behavior research methods & instrumentation, 1975, 7(5): 397-429.

[8] Robinson D A. A method of measuring eye movemnent using a scieral search coil in a magnetic field[J]. IEEE Transactions on bio-medical electronics, 1963, 10(4): 137-145.

[9] Mulligan J B. Image processing for improved eye-tracking accuracy[J]. Behavior Research Methods, Instruments, & Computers, 1997, 29(1): 54-65.

[10] Straumann D, Steffen H, Landau K, et al. Primary position and Listing’s law in acquired and congenital trochlear nerve palsy[J]. Investigative ophthalmology & visual science, 2003, 44(10): 4282-4292.

[11] Clark R A, Miller J M, Demer J L. Displacement of the medial rectus pulley in superior oblique palsy[J]. Investigative ophthalmology & visual science, 1998, 39(1): 207-212.

[12] Oh S Y, Clark R A, Velez F, et al. Incomitant strabismus associated with instability of rectus pulleys[J]. Investigative ophthalmology & visual science, 2002, 43(7): 2169-2178.

[13] Moradizeyveh S, Tabassum M, Liu S, et al. When Eye-Tracking Meets Machine Learning: A Systematic Review on Applications in Medical Image Analysis[J]. arXiv preprint arXiv:2403.07834, 2024.

[14] Chernyak D A. From wavefront device to laser: an alignment method for complete registration of the ablation to the cornea [J]. Journal of Refractive Surgery, 2005, 21(5).

[15] Clemons T E, Rankin M W, McBee W L. Cognitive impairment in the age-related eye disease study: AREDS report no. 16[J]. Archives of Ophthalmology (Chicago, Ill.: 1960), 2006, 124(4): 537-543.

[16] Thomas S L, Thomas S D M. Displacement and health[J]. British medical bulletin, 2004, 69(1): 115-127.

[17] von Hanno T, Lade A C, Mathiesen E B, et al. Macular thickness in healthy eyes of adults (N= 4508) and relation to sex, age and refraction: the Tromsø Eye Study (2007–2008)[J]. Acta ophthalmologica, 2017, 95(3): 262-269.

[18] Lie J T, Birbal R, Ham L, et al. Donor tissue preparation for Descemet membrane endothelial keratoplasty[J]. Journal of Cataract & Refractive Surgery, 2008, 34(9): 1578-1583.

[19] Boote C, Sigal I A, Grytz R, et al. Scleral structure and biomechanics[J]. Progress in retinal and eye research, 2020, 74: 100773.

[20] Tan C S, Chew M C, van Hemert J, et al. Measuring the precise area of peripheral retinal non-perfusion using ultra-widefield imaging and its correlation with the ischaemic index[J]. British Journal of Ophthalmology, 2016, 100(2): 235-239.

[21] Singer M, Sagong M, van Hemert J, et al. Ultra-widefield imaging of the peripheral retinal vasculature in normal subjects[J]. Ophthalmology, 2016, 123(5): 1053-1059.

[22] Palchunova K, Mino T, Mihashi T, et al. Precise retinal shape measurement by alignment error and eye model calibration[J]. Optical Review, 2022, 29(3): 188-196.

[23] De Silva D J, Cocker K D, Lau G, et al. Optic disk size and optic disk-to-fovea distance in preterm and full-term infants[J]. Investigative ophthalmology & visual science, 2006, 47(11): 4683-4686.

[24] Sabri K, Ells A L, Lee E Y, et al. Retinopathy of prematurity: a global perspective and recent developments[J]. Pediatrics, 2022, 150(3).

Downloads