Multi-channel Data Display Software based on fNIRS

Authors

  • Guangmao Zhang
  • Jiabei Chen
  • Jing Yuan
  • Yunfei Ma

DOI:

https://doi.org/10.54097/5f897p34

Keywords:

Functional Near Infrared Spectroscopy, Multi-channel, Data Display

Abstract

This article is to introduce a based on functional near infrared spectroscopy (functionalNear - InfraredSpectroscopy, fNIRS) multichannel data show that the software design and development. According to QtDesigner and VisualStudioCode development, it can quickly calculate and analyze the digital signal sent by Teensy board, and carry out data conversion, real-time display waveform. According to the characteristics of near-infrared spectrum divergence in tissues, the light intensity change signal is converted into the change signal of oxygenated hemoglobin and oxygenated hemoglobin concentration according to the modified Lamberbier law, so as to realize the calculation of hemoglobin concentration, and on this basis, the extraction of low-frequency oscillation signal in blood oxygen concentration is completed. Provides a simple and stable software for changes in hemoglobin oxygenation ([HbO]) and reduction ([Hb]) signals and specific low frequency oscillation (sLFOs) data. 

Downloads

Download data is not yet available.

References

[1] Izzetoglu M, Bunce S C, Izzetoglu K, et al. Functional brain imaging using near-infrare technology[J]. IEEE Engineering in Medicine and Biology Magazine, 2007, 26(4): 38.

[2] Liu Bao-gen, ZHOU Jing, LI Feifei. Functional Near infrared Spectroscopy (fNIRS), a new method for brain functional imaging [J]. Psychological Science,2011,34(04):943-949.

[3] Chief editor Lu Yuguang. Instrumental analysis. China Medical Science and Technology Press, 2016.

[4] Ying Huaiqiao, LIU Jinming, Shen Song, et al. Oversampling /BDFWPS "Anti-miscible" filter research and anti-miscible filter principle [C]// China High-tech Industrialization Research Association Signal Processing Industrialization Branch (Chip). Special issue of the first National Signal Processing Academic Conference and the Third Working Conference of the Preparatory Work Committee of the Signal Processing Branch of the China High-tech Industrialization Research Association. Beijing Dongfang Vibration and Noise Technology Research Institute, 2007:5.

Downloads

Published

27-03-2025

Issue

Section

Articles

How to Cite

Zhang, G., Chen, J., Yuan, J., & Ma, Y. (2025). Multi-channel Data Display Software based on fNIRS. Frontiers in Computing and Intelligent Systems, 11(3), 35-40. https://doi.org/10.54097/5f897p34