Abstract

In order to accurately and timely transmit help-seeking signals from inpatients to medical staff, this system aims to improve the efficiency of hospital medical services and patient satisfaction. It is controlled by Siemens S7-1200 PLC and monitored in real time through the HMI touch screen in TIAPortalv17. Simulation and experimental results demonstrate that the system exhibits high stability and ease of operation, enhancing the efficiency of hospital work and the quality of medical services. Additionally, it boasts convenient operation, stable performance, a simple program, and ease of expansion.

Downloads

Download data is not yet available.

References

[1] Baoqing D ,Haixia X,Junhao L, et al.Research and Development of Intelligent Ward Patient Information Management System Based on PLC[J].International Journal of Computer Theory and Engineering,2021,13(4).

[2] Zeng L ,Yang M,Wang C.Design of NRF24L01 Ward Calling System Based on SINGLE Chip Microcomputer[J].Journal of Research in Science and Engineering,2020,2(6).

[3] Ji M ,He F J .The Design of Ward Calling System Based on SCM[J].Applied Mechanics and Materials,2014,2948(496-500): 1185-1188.