Research on energy-saving conventional submarine air-conditioning system based on heat and humidity load calculation
DOI:
https://doi.org/10.54097/hset.v56i.10703Keywords:
submarine; air conditioner; heat load calculation; cold storage and energy saving.Abstract
The built-in air-conditioning and ventilation system of modern conventional submarines still adopts duct ventilation, which has high working noise, high energy consumption, poor dehumidification effect, and is mainly inter-cooled. For the air quality, hot and humid environment and comfort requirements in the submarine cabin. This project proposes an energy-saving cold storage air-conditioning system suitable for submarines. It adopts the air control method of temperature and humidity independent processing, and combines solution dehumidification and cold storage technology to independently control the temperature and humidity of the cabin, so as to achieve the purpose of efficient dehumidification and energy saving. The system makes full use of the limited space inside the submarine, reduces the energy consumption of refrigeration, improves the underwater endurance and concealment, and provides a healthy and comfortable air environment for the crew of the submarine, which has important strategic value.
Downloads
References
Fang Xiaomin, Song Yichao, Naval Military Representative Office in Guilin, et al. Status and development trend of AIP system technology of foreign conventional submarines [J]. Ship Power Technology, 2015, 35(01): 40-4.
Peng Guangming, China Ship Research and Design Center, Wuhan. Analysis of Oxygen Supply Measures in Submarine Airtight Chambers [J]. Ship and Marine Engineering, 2005, 05): 69-72
Guo Fengtao, Liu Zhongquan, Wang Jinzhong, Chen, et al. Allowable concentrations of air components in the cabin of conventionally powered submarines [J]. PLA Journal of Preventive Medicine, 1994, 04): 255-8
Peng Guangming. Research on atmospheric environment control system of AIP submarine cabin [J]. Chinese Ship Research, 2006, 02): 62-5.
Miao Zhixin, Lian Zhiwei, Zhang Xiaojing, et al. Investigation and actual measurement of residential wet environment in Shanghai in winter [J]. Refrigeration and Air Conditioning (Sichuan), 2017, 31(01): 28-33
Geng Shibin, Guo Hailin, School of Engineering, PLA University of Science and Technology, et al. Humidity load calculation of dehumidification equipment in underground buildings; proceedings of the National HVACR 2000 Academic Annual Conference F,2000 [C].
Zhong Xuexue, Shu Mingjun, Second Artillery Engineering University. Calculation of internal heat and humidity load in underground engineering [J]. Clean and Air Conditioning Technology, 2013, 02): 64-7
He Guohui, Zhong Minjun, Gao Xiang. Transfer function method for calculating the heat load of submarine air-conditioning [J]. Journal of Naval Engineering University, 2002, 03): 45-8+58.
Ma Yunyi. Theory and Technology of Modern Submarine Design [M]. Harbin: Harbin Engineering University Press, 2012.
Lei Yi. Research on design optimization of conventional submarine lighting system [J]. Ship Power Technology, 2017, 37(05): 30-2.
Ma Zuiliang, Yao Yang. Civil Building Air Conditioning Design 3rd Edition [M]. Beijing: Chemical Industry Press, 2015.
Zhang Xing, Chen Ning. Thermal design optimization of high-power submarine power equipment based on FLoEFD [J]. Mechanical Engineering and Automation, 2018, 2): 81-3.
Diao Sufang. Thoughts on the selection of design parameters of HVAC system for offshore oil platforms [J]. Petroleum and Chemical Equipment, 2020, 23(06): 8-10.
Zhong Minjun, Chen Jinzeng, Wu Gang. Energy consumption analysis and energy saving research of a certain type of submarine air conditioner [M]. Proceedings of the 2006 National Conference on Ship Mechanical and Electrical Maintenance Technology. Wuhan. 2006: 391-6.
Li Fucai. Drawing method of heat-moisture ratio line in commonly used enthalpy diagram [J]. HV&AC, 2015, 45(5): 56-8.
Min Yong, Yang Lijuan, Teng Liang. In the design of primary return air conditioning system Analysis of several common problems [J]. HVAC HV&AC, 2009, 39(5): 130-4.
Wu Zanxia, Wu Gang, Zeng Qianghong, et al. Numerical Simulation of Cool Storage Materials Applied to Submarine Air Conditioning [J]. Fluid Machinery, 2008, 36(5): 75-8,34.
Wu Gang, Zeng Qianghong, Chen Jinzeng, et al. Research on using cold storage air conditioner to improve submarine underwater endurance [J]. Ship and Ocean Engineering, 2006, 35(6): 67-9.
Downloads