Meta-analysis of PiCCO monitoring and guiding the use of vasoactive drugs in the treatment of septic shock patients
DOI:
https://doi.org/10.54097/hset.v8i.1178Keywords:
Pulse indicating continuous cardiac output monitoring (PICCO); Septic shock; Systematic review; Meta-analysis; Randomized controlled trialAbstract
As a clinical monitoring method, PiCCO has been widely used in the monitoring of patients with septic shock in recent years. However, it has not been concluded whether PiCCO has more clinical advantages than traditional central venous pressure monitoring. In this paper, 868 literatures were collected through meta-analysis, and 3 literatures meeting the inclusion criteria were screened according to the exclusion criteria set in advance, and a total of 5 studies were obtained.Statistical analysis is conducted by Revman5.4 software provided by Cochrane, and the conclusion is as follows: PICCO monitoring technology can significantly reduce the use of vascular active drugs for patients with purulent septic shock, among which norepinephinxin Z=9.09(P <0.00001), dopamine Z = 4.92 (P <0.00001). Therefore, we recommend using Picco technology clinically.
Downloads
References
Mervyn Singer,Clifford S. Deutschman,Christopher Warren Seymour,Manu Shankar-Hari,Djillali Annane,Michael Bauer,Rinaldo Bellomo,Gordon R. Bernard,Jean-Daniel Chiche,Craig M. Coopersmith,Richard S. Hotchkiss,Mitchell M. Levy,John C. Marshall,Greg S. Martin,Steven M. Opal,Gordon D. Rubenfeld,Tom van der Poll,Jean-Louis Vincent,Derek C. Angus. The Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3)[J]. JAMA,2016,315(8).
Cai Xue, Qin Wei, Zhuang Wenwen. Comparison of intensive ultrasound and PiCCO monitoring in guiding fluid resuscitation in septic shock [J]. Shenzhen Journal of Integrated Traditional Chinese and Western Medicine ,2018,28(04):10-12.DOI:10.16458/j.cnki.1007-0893.2018.04.005.
Liu Yalin, Zou Shuai, Zhao Zhonglin, Wang Xiaorui, Zhang Ting, Chen Yanran .Value of PiCCO monitoring technique in guiding use of fluid resuscitation and vasoactive drugs for patients with septic shock [J]. Chinese Journal of Nosocomiology,2016,26(10):2254-2256.
Zou Hong, Chen Keyu, Zou Yan, Wang Xiaoping, Zhang Chunyan, Wang Fang .Application of PICCO and bedside ultrasound in treatment of patients with septic shock [J/OL]. Chinese Journal of Nosocomiology,2022(05):698-702[2022-04-06].http://kns.cnki.net/kcms/detail/11.3456.R.20220314.1004.028.html
Xia BJ,Shi SY. Application effect of pulse index continuous cardiac output monitoring in the fluid management of infectious shock patients complicated with acute respiratory distress syndrome [J]. Practical Journal of Cardiac Cerebral Pneumal and Vascular Disease,2016,24 ( 5) : 100-102.
Wang Jinli, Chen Jieming, Muen .Analysis of improvement function of fluid management and prognosis in patients with septic shock complicated with acute respiratory distress syndrome by PICCO technology [J].Journal of Clinical Emergency (China),2019,20(09):737-740.DOI:10.13201/j.issn.1009-5918.2019.09.016.
Huang Qingsheng, Li Yan, Fang Xingxing, Guo Jianying, Zhang Huawei, Wang Zhiyong, Zhang Lixia. Application of pulse indicator continuous cadiac output in patients with septic shock complicated with acute respiratory distress syndrome [J].Chinese Journal of Nosocomiology,2017,27(19):4371-4374.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.