Simulation Analysis of ECG Denoising Based on Common Mode Feedback Technology
DOI:
https://doi.org/10.54097/xafxbc59Keywords:
Common mode feedback technology; eliminating; ECG; common mode noise.Abstract
In the global health field, cardiovascular disease has become a major public health problem, early and accurate diagnosis is critical to saving lives, and electrocardiogram (ECG) as a widely used non-invasive diagnostic tool, its signal quality directly affects the diagnostic accuracy. However, the actual ECG signal acquisition is often affected by the internal noise of the organism, the thermal noise of the equipment and the electromagnetic interference of the environment, which leads to the deterioration of signal quality. Therefore, this study focuses on effective methods to suppress the noise of human ECG signals, especially a noise reduction solution based on common mode feedback technology is proposed. In this paper, the importance of ECG signal and the problem of its susceptibility to noise are discussed, which highlights the urgency of using circuit noise reduction technology. Then, the principle of common-mode feedback technology is analyzed deeply, and its superiority in eliminating common-mode noise and enhancing signal-to-noise ratio is revealed. By establishing a simulation model, the differential noise reduction circuit based on load current mirror is simulated by Coolspice software, and the effect of ECG signal noise reduction under simulated noise environment is simulated. The simulation results show that the noise component in ECG signal can be significantly reduced and the signal quality can be effectively improved by using the load current mirror to provide a more accurate and reliable basis for the subsequent ECG data analysis.
Downloads
References
Neycheva T, Dobrev D, Krasteva V. Common-mode driven synchronous filtering of the powerline interference in ECG. Applied Sciences, 2022, 12(22): 11328.
Chen M, Wang J, Anzai D, et al. Common-Mode Noise Reduction in Noncontact Biopotential Acquisition Circuit Based on Imbalance Cancellation of Electrode-Body Impedance. Sensors, 2020, 20(24): 7140.
Rafie N, Kashou A H, Noseworthy P A. ECG interpretation: clinical relevance, challenges, and advances. Hearts, 2021, 2(4): 505-513.
Wang Z, Zhu J, Yan T, et al. A new modified wavelet-based ECG denoising. Computer assisted surgery, 2019, 24(sup1): 174-183.
Rahman M A, Milu M M H, Anjum A, et al. A statistical designing approach to MATLAB based functions for the ECG signal preprocessing. Iran Journal of Computer Science, 2019, 2: 167-178.
Kher R. Signal processing techniques for removing noise from ECG signals. J. Biomed. Eng. Res, 2019, 3(101): 1-9.
Ismail A M, Soliman A M. Novel cmos linearised balanced output transconductance amplifier based on differential pairs. Frequenz, 1999, 53(7-8): 170-174.
Mohieldin A N, Sánchez-Sinencio E, Silva-Martínez J. A fully balanced pseudo-differential OTA with common-mode feedforward and inherent common-mode feedback detector. IEEE journal of solid-state circuits, 2003, 38(4): 663-668.
Gupta V, Gupta A, Chaturvedi, et al. A new technique for improving power supply rejection ratio of amplifier circuit. 2009 International Conference on Advances in Computing, Control, and Telecommunication Technologies. IEEE, 2009: 756-758
Altay Y A, Kremlev A S. Signal-to-noise ratio and mean square error improving algorithms based on newton filters for measurement ECG data processing. 2021 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (ElConRus). IEEE, 2021: 1590-1595.
Downloads
Published
Issue
Section
License
Copyright (c) 2024 Highlights in Science, Engineering and Technology

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.