A High Gain, Low Power Operational Transconductance Amplifier Capable of Recording and Processing ECG Signals

Authors

  • Zhengnan Xuan

DOI:

https://doi.org/10.54097/1r077194

Keywords:

OTA; ECG; denoise; differential pair; human model.

Abstract

Based on high output resistor current mirrors and differential pair inputs, a new operational transconductance amplifier (OTA) is designed in this paper that can collect, filter, denoise and amplify electrocardiogram (ECG) signals. The OTA is designed on a 0.18μm CMOS process with a supply voltage of 1.8V. In this experiment, the ECG signal generated by the human model is first simulated, which has a noise of 50 Hz from electromagnetic interference, especially the electrical power lines. The differential input pair is then connected to the model, and it is proved that it can denoise the common-mode noise. Finally, the designed OTA is connected to the manikin, and the experimental results are compared with the traditional OTA. The design achieves a differential-mode gain of 43.56dB and a common-mode gain of -31.36dB while maintaining a differential input voltage swing of 1Vpp. Experimental results show that the OTA can denoise and amplify the ECG signal without distortion. 

Downloads

Download data is not yet available.

References

Gao Z, Wu J, Zhou J, et al. Design of ECG signal acquisition and processing system. 2012 international conference on biomedical engineering and biotechnology. IEEE, 2012: 762-764. DOI: https://doi.org/10.1109/iCBEB.2012.128

Nayak A, Bonthala S, Uppoor Y, et al. Design of high gain operational transconductance amplifiers in 180 nm CMOS technology. 2019 IEEE International Conference on Distributed Computing, VLSI, Electrical Circuits and Robotics (DISCOVER). IEEE, 2019: 1-4. DOI: https://doi.org/10.1109/DISCOVER47552.2019.9007949

Shahbeigi-Roodposhti P. Acquisition and analysis of an ECG (electrocardiography) Signal. MyJoVE Corporation, 2016.

Altay Y A, Kremlev A S. Comparative analysis of ECG signal processing methods in the time-frequency domain. 2018 IEEE conference of Russian young researchers in electrical and electronic engineering (EIConRus). IEEE, 2018: 1058-1062. DOI: https://doi.org/10.1109/EIConRus.2018.8317272

Patro K K, Kumar P R. De-noising of ECG raw signal by cascaded window based digital filters configuration. 2015 IEEE Power, Communication and Information Technology Conference (PCITC). IEEE, 2015: 120-124. DOI: https://doi.org/10.1109/PCITC.2015.7438145

Kashani A, Barold S S. Significance of QRS complex duration in patients with heart failure. Journal of the American College of Cardiology, 2005, 46(12): 2183-2192. DOI: https://doi.org/10.1016/j.jacc.2005.01.071

Xu L, Zhang X, Yang F, et al. The implementation of single channel ECG and dual channel pulse signals synchronous acquisition system. 2012 IEEE International Conference on Information and Automation. IEEE, 2012: 557-562. DOI: https://doi.org/10.1109/ICInfA.2012.6246876

Deng Yabin. Research and design of CMOS low voltage low power operational transconductance amplifier. Guangxi Normal University, MA thesis, 2017

Lee S Y, Wang C P, Chu Y S. Low-voltage OTA–C filter with an area-and power-efficient OTA for biosignal sensor applications. IEEE transactions on biomedical circuits and systems, 2018, 13(1): 56-67. DOI: https://doi.org/10.1109/TBCAS.2018.2882521

Monfaredi K, Faraji Baghtash H. An extremely low-voltage and high-compliance current mirror. Circuits, Systems, and Signal Processing, 2020, 39(1): 30-53. DOI: https://doi.org/10.1007/s00034-019-01175-1

Gupta M, Aggarwal B, Gupta A K. A very high performance self-biased cascode current mirror for CMOS technology. Analog Integrated Circuits and Signal Processing, 2013, 75: 67-74. DOI: https://doi.org/10.1007/s10470-012-9994-5

Downloads

Published

19-08-2024