Addressing Grid Integration Challenges in Doubly-Fed Wind Turbines: Modeling, Optimization, And Control

Authors

  • Yiting Xiong

DOI:

https://doi.org/10.54097/xjc8mz03

Keywords:

DFIG, MPPT, Modeling optimization, low voltage ride through.

Abstract

As an important means of obtaining clean energy, the doubly-fed wind turbine has undergone significant development and progress. To date, the doubly-fed wind turbine remains a prominent subject of research. This paper investigates and summarizes the maximum power capture of the doubly-fed fan, enhancements to the doubly-fed fan simulation model, and the low-pressure crossing phenomenon in doubly-fed fans. Drawing from the derivation of the maximum power control model of the Doubly Fed Induction Generator (DFIG), the study delves into the maximum power capture of the DFIG, and elucidates the basic model for grid-connected modeling of the doubly-fed wind turbine. Subsequently, an analysis is conducted on the disparity between the DIgSILENT and PSASP models in capturing the maximum power point, and an optimization model for doubly-fed wind turbines is presented based on existing literature. Through a comparison with traditional doubly-fed wind turbine models, the paper highlights the advantages and disadvantages of the optimized model. Finally, an optimization scheme for addressing low-pressure crossing in doubly-fed fans is described, along with a comparative evaluation.

Downloads

Download data is not yet available.

References

Li Wanghui, Bai Ganghua. Maximum wind energy tracking control strategy for brushless doubly-fed wind turbines.Mechanical research and application,2010,23(01):107-109.

Li Wuyan. Research and development of wind turbine simulation system model.North China Electric Power University (Beijing),2011.

Hu Bin. Stable operation analysis and synchronous control strategy of doubly-fed wind turbines connected to the grid.Zhejiang University,2023.DOI:10.27461/d.cnki.gzjdx.2023.000811.

Liu Sijia, Zhuang Shengxian, Shu Xindong. Power control of doubly-fed wind turbine based on stator voltage orientation.Large motor technology,2010,(04):38-41.

Zhang Yu. Simplified dynamic whole process modeling of doubly-fed fan and its influence on transient stability of power system.Taiyuan University of Technology,2022.DOI:10.27352/d.cnki.gylgu.2022.001436.

Chao L, Yunzhu C, Bin L, et al.A novel low voltage ride-through scheme for DFIG based on the cooperation of hybrid energy storage system and crowbar circuit.Journal of Energy Storage,2023,73(PA).

Ma R, Yuan S, Li X, et al.Primary Frequency Regulation Strategy Based on Rotor Kinetic Energy of Double-Fed Induction Generator and Supercapacitor.Energies,2024,17(2).

Liu Shilin,WEN Jinyu,SUN Haishun. A composite energy storage system for wind power regulation and control strategy thereof.Proceedings of the CSEE,2015,35(01):95-102.DOI:10.13334/j.0258-8013.pcsee.2015.01.012.

Gao Yidan. Modeling and grid-connected dynamic characteristics of doubly-fed wind turbines.Huazhong University of Science and Technology,2011.

Han Hualing, Wei Lei, GE Luming et al. DFIG characteristics analysis and protection measures suggestion under different faults of power grid.Power grids and clean energy,2012,28(12):73-78+83.

Downloads

Published