V2G Grid-Tied Inverter System based on LCL Filter with Control Strategy

Authors

  • Rui Song

DOI:

https://doi.org/10.54097/eddc1h14

Keywords:

V2G, Grid-connecting inverter, Active damping, Phase lock loop, LCL filter.

Abstract

Vehicle-to-Grid (V2G) technology has been hotly discussed in recent years because of its broad prospects in load transfer and regulation. This article proposes a grid-connecting inverter system with LCL filter and control strategy for use in electric vehicle (EV) applications. A review of designation of LCL filter’s parameter and mathematic modelling is given in part 2. An explanation of control strategy is given in part 3. Part 4 gives a comparison of active damping and passive damping control strategies with calculated parameters and gives the simulation results based on MATLAB. The results show with parameters calculated with method in article, both strategies have good tracking performance and similar response time. For the critical steady state, passive damping shows higher amplitude of oscillation. This phenomenon gives a new view proof that active damping method is superior than passive damping control strategy. The article is also of some reference value for determining LCL filter’s parameters and proportional, integral coefficient of similar control strategy.

Downloads

Download data is not yet available.

References

Harb A, Hamdan M. Power quality and stability impacts of Vehicle to grid (V2G) connection. 2017 8th International Renewable Energy Congress (IREC). IEEE, 2017: 1-6.

Sovacool B K, Noel L, Axsen J, et al. The neglected social dimensions to a vehicle-to-grid (V2G) transition: a critical and systematic review. Environmental Research Letters, 2018, 13(1): 013001.

Nguyen N, Mitra J. An analysis of the effects and dependency of wind power penetration on system frequency regulation. IEEE Transactions on Sustainable Energy, 2015, 7(1): 354-363.

Liu F, Zha X, Zhou Y, et al. Design and research on parameter of LCL filter in three-phase grid-connected inverter. 2009 IEEE 6th International Power Electronics and Motion Control Conference. IEEE, 2009: 2174-2177.

Xu Jinming, Xie Shaojun, Huang Ruhai. Robust Current control of LCL Filter grid-connected Inverter. Automation of Electric Power Systems, 2012, 36(19): 99-104.

Guo Xiaoqiang, Wu Weiyang, Gu Herong, et al. Modeling and Stability Analysis of Direct Output Current Control in LCL Interface of Grid-connected Inverter. Transactions of China Electrotechnical Society, 2010, 25(3): 102-109.

Xue M Y. Decoupled control and optimized design of grid-connected inverter with LCL filter. Huazhong University of Science & Technology, Wuhan, China, 2012.

Zhao C, Hu Y, Luan K, et al. Energy storage requirements optimization of full-bridge MMC with third-order harmonic voltage injection. IEEE Transactions on Power Electronics, 2019, 34(12): 11661-11678.

Wu R, Dewan S B, Slemon G R. Analysis of an ac-to-dc voltage source converter using PWM with phase and amplitude control. IEEE Transactions on industry Applications, 1991, 27(2): 355-364..

Hudson R M, Thorne T, Mekanik F, et al. Implementation and testing of anti-islanding algorithms for IEEE 929-2000 compliance of single-phase photovoltaic inverters. Conference Record of the Twenty-Ninth IEEE Photovoltaic Specialists Conference, 2002. IEEE, 2002: 1414-1419.

Downloads

Published

19-08-2024